Overview · NVIDIA Blackwell Ultra

The short version. What B300 is, in one card.

NVIDIA's B300 is the Blackwell Ultra data-centre GPU. Here is what it is, what it changes and how XcellHost offers it, before the detail.

Quick answer

What is the NVIDIA B300?

The NVIDIA B300 is the Blackwell Ultra GPU. Per NVIDIA, each one carries up to 288 GB of HBM3e at 8 TB/s, delivers 15 PFLOPS of dense NVFP4 compute (1.5× Blackwell) and runs attention layers 2× faster than Blackwell. GPUs talk over fifth-generation NVLink at 1.8 TB/s each. Eight B300s make an HGX B300 system with 2.1 TB of GPU memory, and 72 of them, with 36 Grace CPUs, make the liquid-cooled GB300 NVL72 rack.

XcellHost takes pre-bookings for B300 capacity in India, from a single-GPU instance* to full racks. We confirm availability, allocation and the delivery window in your quotation, deploy the hardware in our Mumbai Tier IV data centre or a partner liquid-cooled facility*, and run it 24×7.

At a glance per NVIDIA
0GB HBM3e per GPU (max)
0TB/s memory bandwidth
0PFLOPS dense NVFP4
0×attention speed vs Blackwell
0TB/s NVLink per GPU
0TB HBM3e per HGX B300

Precisions: NVFP4, FP8/FP6, FP16/BF16, TF32, FP32 and FP64 · 5th-generation Tensor Cores · PCIe Gen 6

Illustration · B300 SXM module
Meet the NVIDIA B300

Blackwell Ultra, built for what comes after big models.

Some AI jobs need more than raw compute. They need room: room for model weights, for long prompts, and for the key-value cache that grows with every reasoning step. Earlier Blackwell GPUs start to run short of that room on the largest mixture-of-experts and dense transformer models. B300 adds it.

Per NVIDIA, Blackwell Ultra raises memory to 288 GB of HBM3e per GPU, 50% more than Blackwell and 3.6× an H100. Dense NVFP4 compute rises 1.5× to 15 PFLOPS, and new attention acceleration doubles the speed of the layers reasoning models spend most of their time in.

XcellHost lets you use that hardware without buying it. Pre-book a configuration, and we confirm allocation and a delivery window, then host, cool and run it for you. Fine-tune a mid-size model on part of a server, or reserve a multi-node cluster for a quarter-long training run, under one contract billed in rupees.

  • More memory per GPULarger models and longer context on fewer GPUs.
  • Faster reasoning2× attention-layer throughput, per NVIDIA.
  • No capexReserve capacity instead of buying and cooling it.
B300 GPU · technical specifications

Every published figure, grouped the way engineers read it.

From NVIDIA's Blackwell Ultra architecture brief and HGX B300, DGX B300 and GB300 NVL72 product pages. Per-GPU figures unless a card says otherwise. Pick a group.

Architecture

GPU generationNVIDIA Blackwell Ultra
Process & transistorsTSMC 4NP · 208 billion transistors
PackageTwo reticle-sized dies joined by NV-HBI at 10 TB/s, seen by software as one GPU
Tensor Cores5th generation, with NVFP4 support · 4 per SM
SMs & CUDA cores128 CUDA cores per SM · up to 160 SMs on the full die; shipping counts vary by SKU
Form factorSXM module on the HGX B300 8-GPU baseboard, or in GB300 Grace Blackwell Ultra superchips

Memory

GPU memoryUp to 288 GB HBM3e per GPU (capacity varies by SKU)
Stacks & interfaceEight 12-high HBM3e stacks · 8,192-bit
Bandwidth8 TB/s per GPU · 2.4× an H100
HGX B300 total2.1 TB of GPU memory across 8 GPUs
GB300 NVL72 total20 TB HBM3e (up to 576 TB/s) plus 17 TB LPDDR5X on Grace · 37 TB fast memory
Partitioning (MIG)For example 2 × 140 GB, 4 × 70 GB or 7 × 34 GB instances

Performance

NVFP4 · per GPU15 PFLOPS dense · 20 PFLOPS sparse
FP8 · per GPU5 PFLOPS dense · 10 PFLOPS sparse
FP4 · HGX B300 (8 GPUs)108 PFLOPS dense · 144 PFLOPS sparse
FP8 / FP6 · HGX B30072 PFLOPS with sparsity
FP16/BF16 · TF32 · HGX36 PFLOPS · 18 PFLOPS, with sparsity
FP32 · FP64 · HGX600 TFLOPS FP32 · 10 TFLOPS FP64 per 8-GPU system

Connectivity

NVLink5th generation · 1.8 TB/s per GPU (18 links × 100 GB/s, bidirectional)
HGX B300 fabricNVLink 5 Switch · 14.4 TB/s total NVLink bandwidth
NVLink domainUp to 576 GPUs in a non-blocking NVLink fabric
Host linksPCIe Gen 6 x16 (256 GB/s) · NVLink-C2C 900 GB/s to Grace
Scale-out networkConnectX-8 SuperNIC · 800 Gb/s per GPU · Quantum-X800 InfiniBand or Spectrum-X Ethernet
HGX B300 networking1.6 TB/s per system (2× HGX B200)

Power & Thermal

GPU powerUp to 1,400 W per GPU (Blackwell: 1,200 W · Hopper: 700 W)
DGX B300 systemAbout 14 kW per 10U, 8-GPU system
GB300 NVL72Fully liquid-cooled rack-scale design
HGX serversCooling depends on the server platform; XcellHost plans air or direct-to-chip liquid per build*
Facility planningRack power, cooling loop and floor loading are confirmed in your design and quotation*

Advanced Features

Attention acceleration10.7 TeraExponentials/s in the SFU, about 2× Blackwell, for faster softmax in attention layers
NVFP4 precision4-bit floating point for inference and training, with 1.5× the dense NVFP4 of Blackwell
Multi-Instance GPUSplit one GPU into isolated instances for smaller jobs
Dual-die, one GPUNV-HBI keeps two dies coherent at 10 TB/s
Rack-scale NVLink72 GPUs in one NVLink domain in GB300 NVL72

Target Workloads

Reasoning inferenceLong-context and test-time reasoning, where attention and KV cache dominate
Frontier trainingPre-training and fine-tuning large dense and mixture-of-experts models
Agentic AIMulti-step agents that call tools and keep long histories
Video & multimodalDiffusion video, image and speech generation with large batches
Note on FP64An HGX B300 lists 10 TFLOPS FP64 per system; FP64-heavy simulation may suit H200 better

Software Support

NVIDIA stackCUDA, cuDNN, TensorRT, TensorRT-LLM, NVIDIA Dynamo, Triton, NeMo, NIM
FrameworksPyTorch, JAX, TensorFlow
Serving enginesvLLM, SGLang, TensorRT-LLM
OrchestrationKubernetes, Slurm, Docker · NVIDIA Mission Control on DGX
Operating systemsDGX OS, Ubuntu, Red Hat Enterprise Linux, Rocky Linux
EnterpriseNVIDIA AI Enterprise licensing quoted on request*

Sources: NVIDIA Technical Blog "Inside NVIDIA Blackwell Ultra"; nvidia.com HGX, DGX B300 and GB300 NVL72 pages (checked 24 October 2026). Peak theoretical figures, not measured performance. Software versions are agreed and tested per deployment.

Choosing between generations

B300, B200, H200 or H100? Pick by workload, not by headline.

Four NVIDIA data-centre GPUs are in production use today. The right one depends on model size, how much memory headroom you need and what you want to spend. These are NVIDIA's published per-GPU figures, side by side.

AttributeNVIDIA H100NVIDIA H200NVIDIA B200NVIDIA B300
ArchitectureHopperHopperBlackwellBlackwell Ultra
Process · transistorsTSMC 4N · 80BTSMC 4N · 80BTSMC 4NP · 208BTSMC 4NP · 208B
GPU memory80 GB HBM3141 GB HBM3e192 GB HBM3e288 GB HBM3e
Memory bandwidth3.35 TB/s4.8 TB/s8 TB/s8 TB/s
Tensor Core generation4th4th5th5th
NVFP4 (dense · sparse)not supportednot supported10 · 20 PFLOPS15 · 20 PFLOPS
FP8 (dense · sparse)~2 · ~4 PFLOPS~2 · ~4 PFLOPS5 · 10 PFLOPS5 · 10 PFLOPS
Attention (SFU EX2)4.5 TExp/s4.5 TExp/s5 TExp/s10.7 TExp/s
NVLink per GPU900 GB/s900 GB/s1.8 TB/s1.8 TB/s
PCIeGen 5 · 128 GB/sGen 5 · 128 GB/sGen 6 · 256 GB/sGen 6 · 256 GB/s
Max powerup to 700 Wup to 700 Wup to 1,200 Wup to 1,400 W
Best fitProven, widely deployed training and inferenceMemory-hungry inference on Hopper, FP64 HPCLarge-model training and inferenceFrontier-scale, memory-bound, long-context reasoning
1.5×GPU memory vs B200
3.6×GPU memory vs H100
7.5×dense NVFP4 vs Hopper's dense FP8
2×attention speed vs Blackwell

Per NVIDIA's Blackwell Ultra architecture brief (Hopper, Blackwell and Blackwell Ultra columns) and the H200 product page. Hopper FP8 rounded as NVIDIA lists it; H200's page gives 3,958 TFLOPS FP8 with sparsity. Shipping SKUs can differ. XcellHost's line-up today includes H200; B300 is pre-booked and other GPUs are sourced on request.

Configurations

One GPU to a full rack. Every option is price on quote.

Start with the GPU count your model needs. The shapes below show typical vCPU and RAM pairings. Your quotation confirms the exact CPU, RAM, storage, network, allocation and delivery window.

1× B300*

Single-GPU instance

GPU memory
up to 288 GB HBM3e
vCPU · RAM
32 · 256 GB*
GPU-to-GPU
n/a (one GPU)
Network
sized in quote

Good for fine-tuning, evaluation and serving one large model.

Price on quoteconfirmed at quote*Pre-book →
2× B300*

Dual GPU

GPU memory
2 × up to 288 GB
vCPU · RAM
64 · 512 GB*
GPU-to-GPU
NVLink 1.8 TB/s
Network
sized in quote

Good for 400B-class models at NVFP4 with long context.

Price on quoteconfirmed at quote*Pre-book →
4× B300*

Half server

GPU memory
4 × up to 288 GB
vCPU · RAM
128 · 1,024 GB*
GPU-to-GPU
NVLink 1.8 TB/s
Network
sized in quote

Good for full fine-tuning of 30–70B models, mid-size MoE.

Price on quoteconfirmed at quote*Pre-book →
Full HGX server 8× B300

HGX B300 server

GPU memory
2.1 TB HBM3e
vCPU · RAM
256 · 2,048 GB*
GPU-to-GPU
NVLink Switch · 14.4 TB/s
Network
up to 1.6 TB/s per system

Good for frontier fine-tuning, MoE training, high-volume reasoning inference.

Price on quoteconfirmed at quote*Pre-book →
Multi-node

HGX B300 cluster

Two or more HGX B300 servers joined by a scale-out fabric: NVIDIA Quantum-X800 InfiniBand or Spectrum-X Ethernet with ConnectX-8 SuperNICs at up to 800 Gb/s per GPU*. We design the fabric, storage and scheduler (Slurm or Kubernetes) with you.

  • Rail-optimised fabric design
  • Parallel and object storage sized to your data
  • Slurm or Kubernetes, tested end to end
Price on quotedesigned per project*Pre-book →
Illustration
Rack-scale

GB300 NVL72 rack

Per NVIDIA: 72 Blackwell Ultra GPUs and 36 Grace CPUs in one fully liquid-cooled rack, acting as one NVLink domain with 130 TB/s of NVLink bandwidth, 20 TB of HBM3e and 1.1 exaFLOPS of dense FP4. Hosted in a liquid-cooled facility, XcellHost's or a partner's*.

  • Direct-to-chip liquid cooling
  • 37 TB fast memory per rack
  • Facility and power confirmed at quote*
Price on quoteconfirmed at quote*Pre-book →

GPU figures per NVIDIA. *Single-GPU and partial-server instances, vCPU and RAM pairings, network options and hosting facility are indicative and confirmed in your quotation. No prices are published for any B300 configuration; GST at 18% is added to the quoted amount.

B300 allocations are limited. Get in the queue early.Tell us the configuration and the date you need it. We confirm allocation and a delivery window in writing.
Pre-book B300 →
What teams run on B300

Built for the workloads that outgrew the last generation.

Six workload types where more memory, faster attention and NVFP4 make the biggest difference. Each card shows a sample starting configuration; we size yours in the quotation.

Reasoning LLM inference

Serve reasoning models that think in long chains. Attention acceleration and large KV caches keep tokens per user high.

Sample: 1–8 GPUs · TensorRT-LLM / vLLM

Training & fine-tuning

Pre-train or fine-tune 200B+ parameter dense and mixture-of-experts models with FSDP, DeepSpeed or Megatron across NVLink.

Sample: 8–64 GPUs · NeMo / PyTorch

Agentic AI

Agents that plan, call tools and keep long histories need memory headroom and fast prefill. B300 has both.

Sample: 2–8 GPUs · NIM / Dynamo

Video & multimodal

Diffusion video, image and speech generation with large batches. NVIDIA cites up to 30× faster real-time video generation on GB300 NVL72 than Hopper.

Sample: 8 GPUs · PyTorch

Scientific AI

Protein models, drug discovery, climate and materials AI that run at low precision. FP64-heavy simulation still suits H200.

Sample: 8–16 GPUs · CUDA

Enterprise AI platforms

Rack-scale capacity for an organisation-wide model platform, shared across teams with quotas, MIG and audit logs.

Sample: GB300 NVL72 · Kubernetes
Illustration · open HGX B300 server
Why XcellHost

Why businesses choose XcellHost to pre-book B300 capacity.

Owning B300 servers outright means paying for the hardware, the network, the liquid cooling and the depreciation before a single job runs. Reserving through XcellHost moves all of that to us. You get Blackwell Ultra capacity sized to your project, with allocation and delivery confirmed in writing.

  1. Quotations you can readWe show what drives your rate (GPU count, term, cooling, network and managed scope) instead of one opaque number.
  2. Grow without re-architectingStart on a single-GPU instance* and move to an HGX B300 server, a cluster or a GB300 NVL72 rack under one contract.
  3. Liquid cooling planned inDirect-to-chip cooling and high-density racks in our Mumbai Tier IV facility or a partner liquid-cooled site*. How we cool AI racks →
  4. Engineers who answer24×7 NOC and SOC in Mumbai, reachable by phone, WhatsApp and email.
  5. Hosted in India, billed in rupeesData, weights and logs stay in India. One INR invoice with GST.
  6. Honest availabilityAllocation and delivery are confirmed at quote*. If you need GPUs now, we can bridge you on H200.
Facility requirements

B300 needs more power and cooling. We plan for it before it ships.

Blackwell Ultra draws more power per GPU than any NVIDIA GPU before it. That changes rack power, the cooling method and the network. These are NVIDIA's figures and what they mean for your deployment.

0 Wper B300 GPU, up from 700 W on Hopper
~0 kWper DGX B300 system (10U, 8 GPUs)
100%liquid-cooled: the GB300 NVL72 rack design
0 Gb/snetwork per GPU with ConnectX-8 SuperNICs
PowerSeveral HGX B300 servers fill a high-density rack quickly. We size feeds, redundancy and the power budget per rack in the design.
CoolingGB300 NVL72 needs direct liquid cooling. HGX servers use air or liquid depending on the platform; we pick the method that fits.
NetworkingMulti-node jobs need a non-blocking InfiniBand or Spectrum-X fabric, designed rail by rail before cabling.

Power and cooling figures per NVIDIA (Blackwell Ultra brief, DGX B300 and GB300 NVL72 pages). Rack density, cooling method and facility are confirmed for each deployment at quote*.

How XcellHost delivers

From reservation to running jobs, we handle the hard parts.

A B300 reservation is only useful once power, cooling, network, drivers and monitoring all work together. Six stages, one accountable team.

01

Sizing

Model, precision, context, users and timeline turned into a GPU count, network and storage plan.

02

Allocation

We place your reservation and confirm allocation and a delivery window in writing at quote*.

03

Rack & cooling

Power feeds, liquid or air cooling and rack layout prepared in our Mumbai Tier IV DC or a partner site*.

04

Deployment

Racking, cabling, firmware, drivers, CUDA and NCCL tests, burn-in and fabric checks before handover.

05

24×7 operations

GPU health, thermals, memory errors and network watched by our NOC; access watched by our SOC.

06

MLOps

Optional Kubernetes or Slurm, model registry and inference endpoints as part of our AI Factory.

India first

Frontier GPUs, with your data kept in India.

B300 capacity from XcellHost is hosted in India and operated from Mumbai. Training data, prompts, outputs, model weights and logs stay on infrastructure we run here, and admin access sits with our own NOC and SOC staff.

0 hCERT-In incident reportingCERT-In's April 2022 directions ask for cyber incidents to be reported within 6 hours. Our SOC keeps the evidence trail.
0 dLogs kept in IndiaThe same directions ask for ICT logs to be kept for 180 days within Indian jurisdiction. Node and access logs stay in Mumbai.
2023DPDP ActThe Digital Personal Data Protection Act 2023 and its Rules cover personal data used to train or prompt models. In-India processing helps you meet your obligations.
2024IndiaAI MissionApproved by the Union Cabinet in March 2024 to widen access to AI compute in India. Domestic GPU capacity fits that direction.

Hosting in India supports your compliance evidence; on its own it does not make you compliant. Notices, consent, retention and model-risk processes remain your responsibility. XcellHost's ISO 27001, 27017, 27018 and 20000-1 certifications, SOC 2 Type I & II and MeitY empanelment cover our own operations. This is not legal advice.

Configure · quotation

Build your B300 reservation. We confirm allocation and price.

Choose the configuration, quantity, term and where it runs. The summary updates as you go. XcellHost replies with allocation, a delivery window and a rupee quotation with GST shown separately.

1 server = 8 B300 GPUs
Quotation summaryXH-B300 · draftPrice on quote
PricingOn quotation · INR · excl. 18% GST
Tool · model memory fit

Will your model fit in 288 GB? Work it out here.

Parameters × bytes per parameter, plus headroom for the KV cache and runtime, divided by GPU memory. The answer is illustrative; we confirm it with a test run.

Raise this for long context, reasoning traces or many concurrent users.
Estimated GPU memory0 GBillustrative
Weights / states 0Headroom 0Free
NVIDIA B3001×
NVIDIA B200 · 192 GB1×
NVIDIA H200 · 141 GB1×
NVIDIA H100 · 80 GB1×

—

Show the formula
    Use in pre-booking →
    Tool · spec comparer

    B300 against H200 or B200, on NVIDIA's own numbers.

    Vendor specifications only. No prices, no benchmarks. Pick a GPU and dense or sparse tensor figures; bars scale to the larger value in each row.

    NVIDIA B300NVIDIA H200
    Where B300 leads
      When the other GPU may fit

        Per NVIDIA's Blackwell Ultra architecture brief and the H200 product page. Hopper has no NVFP4; the low-precision row compares B300 NVFP4 with Hopper FP8. Peak theoretical numbers do not predict real throughput.

        Compare

        Pre-book with XcellHost, join a hyperscaler waitlist, or buy your own. How they differ.

        All three can get you Blackwell Ultra. They differ in who runs it, where it sits and how you pay.

        Pre-book with XcellHostHyperscaler waitlistBuy & host yourself
        AvailabilityAllocation and delivery window confirmed in writing at quote*Quota requests and regional waitlistsOEM lead times, then your build-out
        LocationIndia: Mumbai Tier IV or partner liquid-cooled site*Region by choice; B300 regions varyYour premises or co-location
        BillingINR quotation + GST, monthly or reservedUsage-based, often USD-linkedLarge upfront capex plus AMC
        Power & coolingPlanned and run by usIncludedUp to 1,400 W per GPU and liquid cooling to build
        SetupDrivers, CUDA, NCCL and frameworks tested before handoverYou build the imagesYou install and maintain everything
        Support24×7 NOC & SOC in MumbaiTiered support plansYour staff plus vendor warranty
        Bridge capacityH200 available while you waitDepends on quotaNone until delivery
        How to pre-book

        From request to running cluster. Five steps.

        Delivery depends on NVIDIA supply and how much of the stack you want managed. Your quotation states the window.

        1. 01Share the workload

          Model, precision, users, data rules and target date.

        2. 02Sizing & design

          GPU count, network, storage, power and cooling.

        3. 03Quotation & allocation

          INR quotation, GST separate, allocation and window confirmed*.

        4. 04Deploy & test

          Racked, cooled, burned in, fabric-tested, handed over.

        5. 05Run 24×7

          Monitoring, patching, monthly reports and reviews.