IEC 62443 is the international series of standards for cybersecurity in industrial automation and control systems — the PLCs, SCADA, DCS and safety systems that run plants, utilities and infrastructure. Developed by ISA's ISA99 committee and published by IEC, it sets requirements for asset owners, service providers and product suppliers, divides systems into zones and conduits, and defines Security Levels 1 to 4 that state how determined an attacker each zone must resist.
XcellHost is ISO 27001 and ISO 20000-1 certified · Indian Tier-4 datacenters · DPDPA and RBI aligned · 24×7 NOC and SOC.
Explore security Levels 1–4 and the attacker resisted. Select the sections in the interactive explorer above to see the requirements and how XcellHost helps.
IEC 62443 is not mandated across Indian industry, but it is the OT standard Indian regulators and large buyers reach for. Power-sector guidance cites it for equipment, BIS publishes parts of it as Indian Standards, and PSU and private tenders in energy and process industries increasingly specify it.
We have much better visibility across our employee devices now. Suspicious activity is easier to spot, and our team can respond quickly when something unusual occurs.
Managing security across multiple endpoints has become much simpler. Centralized monitoring saves our team time, while clear alerts help us focus on important threats.
The behavioral approach gives us more confidence than relying on traditional antivirus alone. We can identify unusual activity earlier and take action before it affects our operations.
They are the same series. ISA's ISA99 committee writes the documents, ISA publishes them as ANSI/ISA-62443, and IEC adopts them internationally as IEC 62443. Edition dates can differ by a year or so between the two publishers, but the technical content is aligned.
Identification and authentication control, use control, system integrity, data confidentiality, restricted data flow, timely response to events, and resource availability. Parts 3-3 and 4-2 organise their technical requirements under these seven headings, with additional requirement enhancements at each higher security level.
They describe the attacker a zone or component must resist: SL 1 casual or accidental misuse, SL 2 intentional attack with simple means and low resources, SL 3 sophisticated means with moderate resources and control-system skills, SL 4 sophisticated means with extended resources and high motivation. SL 0 means no specific requirement.
Not as a general law. The CEA's 2021 power-sector guidelines call for IEC 62443-4 conformant equipment, BIS has adopted parts of the series as Indian Standards, and many PSU and private tenders specify it. For other sectors it is the recognised good practice that NCIIPC and auditors expect to see.
Yes, through schemes such as ISASecure and the IECEE CB scheme, which certify products (4-2), development processes (4-1), systems (3-3) and service provider capabilities (2-4). Certificates are issued by accredited bodies; XcellHost prepares you and your products for them but does not issue them.
We assess plants against the standard, model zones and conduits, set target security levels, and then run the controls: industrial endpoint protection, passive network monitoring, patching, remote access and backup. For product makers we review secure development practices and test devices against 4-2 ahead of certification.
Explore practical guides and expert insights on cloud, cybersecurity and Indian compliance to help your business move forward.